Sign In | Join Free | My himfr.com
Home > Magnetostrictive Level Gauge >

Anti Corrosion Magnetostrictive Level Gauge HART Float Level Transmitter

Xi'an Dehou Electronic Technology Co., Ltd.
Trust Seal
Verified Supplier
Credit Check
Supplier Assessment
Contact Now
    Buy cheap Anti Corrosion Magnetostrictive Level Gauge HART Float Level Transmitter from wholesalers
     
    Buy cheap Anti Corrosion Magnetostrictive Level Gauge HART Float Level Transmitter from wholesalers
    • Buy cheap Anti Corrosion Magnetostrictive Level Gauge HART Float Level Transmitter from wholesalers
    • Buy cheap Anti Corrosion Magnetostrictive Level Gauge HART Float Level Transmitter from wholesalers

    Anti Corrosion Magnetostrictive Level Gauge HART Float Level Transmitter

    Ask Lasest Price
    Brand Name : NUOYINGJIAYE
    Model Number : NYCZ
    Certification : Explosion-proof certificate
    Price : $240 to $1900
    Payment Terms : T/T
    Supply Ability : 300 pcs/ pre month
    Delivery Time : 7 work days
    • Product Details
    • Company Profile

    Anti Corrosion Magnetostrictive Level Gauge HART Float Level Transmitter


    Magnetostrictive Liquid Level Meter


    Magnetostrictive Liquid Level Meter Operating Principle

    Magnetostrictive liquid level sensor (hereinafter referred to as sensor, including common type and flameproof type) is used for continuous measurement of liquid level and interface. In addition, magnetostrictive liquid level sensors are also widely used in various fields, including industrial measurement and control of liquid levels in various liquid tanks such as petroleum, storage of chemical raw materials, industrial processes, biochemistry, medicine, food and beverage, tank farm management and underground storage of gas stations, dam water level, reservoir water level monitoring and sewage treatment, etc.


    Magnetostrictive level gauge consists of three parts: probe rod, circuit unit and float. To measure, the circuit unit generates pulses of current that travel down the magnetostrictive line and generate a circular magnetic field. A float is arranged outside the probe rod, and the float moves up and down along the probe rod with the change of liquid level. The float generates a magnetic field at the same time because it is fitted with a set of permanent magnets. When the current magnetic field meets the float magnetic field, it produces a "twisting" or "return" pulse. The time difference between the "return" pulse and the current pulse is converted into pulse signals to calculate the actual position of the float and measure the liquid level.


    Magnetostrictive Liquid Level Meter Technical Parameter


    Applicationsliquid level
    Measurement range

    Probe: 0-50~6000mm

    Cable: 25m

    Accuracy±0.5mm
    Power supply24VDC ±10%
    Signal output4~20mA / Hart / RS485
    Working current4~20mA; 20.4mA
    Load characteristicswhen current output, maximum load resistance 600 Q voltage output, maximum load Resistance 2mA
    Process temperature-40〜130 °C,-40〜250 °C
    Ambient temperature-40〜80°C
    Temperature effect±0.5 °C
    Process pressure- 0.1 ~ 4.0MPa
    Resolution±lmm
    Response time0.2 ms
    Rod material304/316L (optional)
    Process connectionThread, flange, Support mounting (optional)
    Site displayLCD (optional)
    Housing materialstainless steel / aluminum (optional)
    Protection gradeIP67
    Explosion proof gradeExia IICT6 (optional)


    Note: Products can be customized according to the specific requirements of users!

    Magnetostrictive level gauge antenna using PTFE material, PTFE (PTFE or PTFE), commonly known as "plastics king", is made up of tetrafluoroethylene by the polymerization of polymer compounds, it has excellent chemical stability, high corrosion resistance, sealing, lubrication is not sticky, electric insulation and good anti-aging endurance, PTFE has the following features:

    • High temperature resistance -- operating temperature up to 250℃.
    • Low temperature resistance -- good mechanical toughness; Even when the temperature drops to -196℃, 5% elongation can be maintained.
    • Corrosion resistance - inert to most chemicals and solvents, resistant to strong acids and bases, water and various organic solvents.
    • Weather resistance - has the best aging life of plastics.
    • High lubrication - the lowest friction coefficient of solid materials.
    • Non-adhesion - is the minimum surface tension in a solid material and does not adhere to any substance.
    • Non-toxic -- with physiological inertia, as artificial blood vessels and organs implanted in the body for a long time without adverse reactions.

    Anti Corrosion Magnetostrictive Level Gauge HART Float Level Transmitter

    Magnetostrictive Liquid Level Meter Typical Application And Installation


    • Measure the level of horizontal storage tanks: top mounted
    • For production control, side to side installation
    • Used for middle liquid level control in production: side to side installation
    • Application and installation of large vertical oil tank
    • Application on vertical oil tanks: soft cable top mounting
    • Matching application with magnetic plate level meter
    • Application and installation of asphalt storage tank

    Quality Anti Corrosion Magnetostrictive Level Gauge HART Float Level Transmitter for sale
    Inquiry Cart 0
    Send your message to this supplier
     
    *From:
    *To: Xi'an Dehou Electronic Technology Co., Ltd.
    *Subject:
    *Message: